Maintenance to the air filter

Dust in the combustion air can cause premature wear of  the engine. Maintenance of the air cleaner is therefore essential to ensure  long life. It is also necessary to check unions and connections of the intake  manifold regularly.

Oil bath type air cleaner

The maintenance should only be made after shutting down the engine and waiting for at least one hour.

In the case of moderate dust conditions, the oil-bath type air cleaner must be taken apart once a year, replace the oil in the  cleaner bowl, and the fixed upper metal wool must be cleaned repeatedly  immersion in diesel fuel. In case of extreme dust conditions, this procedure  should be carried out twice a year. When disassembling and reassembling the  air cleaner, make sure that the rubber gasket on the cleaner bowl is not  damaged.

Always remember that only a clean air cleaner will give  clean combustion air, which is so vital for high engine performance and low  wear.

Paper-element type air cleaner

When the engine is stopped, remove the bowl, take out   the element, and clean it. If the element has defects, replace it   immediately. Remember that the element should be replaced at lease once a  year.

The following is the cleaning methods for the element.

1.Tap the element gently with its front end against  the palm of your hand or on a soft surface to shake off the dust. Take care  not to damage the front end of the element.

2.Apply air blast of max 5X10 5 Pa diagonally inside  and out until no more dust is coming out.

Caution: Do not wash the element with any liquid

Prior to reassembly, introduce a lighted bulb into the  filter element to see whether it suffered damage(damaged elements must be  replaced timely)

Attention, If the alarm indicator stay in the green  sector, it means the air filter can work normally, while if the alarm  indicator goes to the red sector, it`s time to do the maintenance.

Maintenance Keys:

1. Clean dust and dirt timely

2. Change filter cartridge(when alarm indicator   turn on)

3. Press vacuum mechanical indicator button after   maintenance done